This is HQ EV CLINIC Lab for EV Research and Development, EVC Academy trainings, franchising and Networking. For service appointement, choose franchise locations. Dismiss
This operation manual is a proprietary business secret that outlines the successful refurbishment process for repair Motor inverter system and data recovery. By following the provided instruction steps, which include text, images, and videos, you will be fully equipped to repair the Inverter effectively and efficiently. Manual is non-refundable
You can charge this service: 3500€ You need 16 labor hours to deploy this repair if you are removing battery pack BMW OEM CHARGE: PTC 950€+tax EME 7000€+tax Labor 2000€+tax Author: Domagoj
Common causes:
Shorted PTC
Shorted KLE
Errors:
21E720,
0316D8,
030EC1,
030ECD,
Charging doesnt work
Part numbers:
64 12 9 873 688,
64 12 5 A66 1F9,
1236 102135 68,
Tools needed (prepare it) :
Workshop lift (PTC below the vehicle)
Allen key 5,6,7,8,9.10
Torx 5,6,7,8,9.10
Fluke Voltmeter
Repair kit - Replacement parts
OBD Diagnostic
HV Gloves
Repair operation steps
Step 1:
Before performing any work on the eGolf high-voltage Drive unit, it is mandatory to prepare a controlled and safe working environment in accordance with high-voltage safety protocols. Lvl 3 HV Access license needed.
Read error codes with diagnostic tool and confirm you have same error codes and faults.
Secure the work area – The workspace must be clean, dry, clearly marked as an HV zone, and equipped with proper safety gear (HV gloves, face shield, insulating mat).
Disconnect the 12V system
Perform safe high-voltage system shutdown – Using approved tools and following OEM procedures, disconnect the HV connectors and wait the required cool-down period for capacitor discharge.
Verify absence of voltage (Zero Voltage Verification) – Use an appropriate HV tester to ensure that no voltage is present in the system before proceeding.
Remove the battery pack – Once confirmed safe, proceed with mechanical removal of the battery pack using factory mounting points and proper lifting equipment
Proceed with PTC removal and change which is underneth car. Disconnect all HV lines from KLE and then remove PTC. Remember, PTC is shorted and needs to...
You have reached a restricted content! You must buy this online training operation manual to get access.
Important for ALL customers! 🚗⚡
Our lab is located on a secured site with access control and closed gates, spontaneous visits are not possible!
Due to high demand and our limited capacity, we may not be able to respond to your requests immediately. Delays of up to 2 weeks are possible due to multiple employees being sick and a shortage of workforce.
📅 Please schedule an appointment in advance via email so we can register your access. Visits without invitation is forbiden.